Cable Distribution Cabinets

Shop directly from our factory for high-quality cable distribution cabinets. Get top-notch products at affordable prices for all your cable management needs.

Request a Quote
  • Cable Distribution Cabinets
  • Cable Distribution Cabinets

PRODUCTS DETAILS

Cable Distribution Cabinet

The cable distribution cabinet adopts component module assembly and frame assembly structure, and the bus and feed out are insulated enclosed.


Five structural types can be adopted:

1. The incoming line adopts insulated enclosed disconnector, and the outgoing line adopts MCCB;

2. The incoming line adopts insulated enclosed disconnector, and the outgoing line adopts knife fuse switch;

3. The incoming line adopts strip disconnector and the outgoing line adopts strip switch (with fuse protection);

4. The incoming line does not have a switch, and the outgoing line adopts a knife melting switch;

5. The incoming and outgoing lines are not equipped with switches.


Executive standard

IEC269 Low voltage fuse

IEC282/1 Current limiting circuit breaker

IEC517 Rated voltage 1kv~ 36kv High Voltage AC and control insulation

IEC439 Low voltage switchgear and control equipment package

IEC144-63 Protection level of enclosures of low voltage switchgear and control equipment

IEC364.3.1 Electrical equipment of buildings Part 3 "General requirements for installation equipment" chapter I safety


Service Environment

No

Item

Unit

Guarantee Value

1

Ambient air
temperature

Max air temperature

+45

Min air temperature

-25

Max daily temperature
difference

K

30

2

Altitude

m

≤1000

3

Humidity

Average daily relative humidity

%

≤95

Average Monthly relative humidity

≤90

4

Earthquake resistance (horizontal acceleration)

m/s2

0.2g


Technical Data

No

Name

Item

Unit

Technical data

One

General technical data

1

Enclosure

Installation


Outdoor/Indoor
Ground mounted/Wall mounted

Enclosure Material


S304 Stainless steel

Protection Level


IP44

Measurement


See the drawing

2

Bus-bar

Rated working Voltage

V

400

Rated frequency

Hz

50

Rated current

A

630

Rated insulation voltage

V

660

Rated short-circuit withstand current


10kA, 1S

Bus-bar Material


Copper

Two

The incoming line adopts insulated enclosed disconnector, and the outgoing line adopts MCCB;

1

MCCB

Number of poles


3P

Release type


Electronic

Rated working Voltage

V

400

1

MCCB

Rated insulation voltage

V

660

Rated current

A

250/160

Rated short-circuit withstand current

kA

10

Rated ultimate breaking capacity

kA

50

2

Disconnector

Rated short-circuit withstand current


10kA, 1S

Rated current

A

400/630

Rated working Voltage

V

400

Rated insulation voltage

V

660

Number of poles


3P



Hot Products

3D Wound Core Transformer

3D Wound Core Transformer

24kV Three Phase Oil Fill Power Transformer

24kV Three Phase Oil Fill Power Transformer

Low Voltage Distribution Board

Low Voltage Distribution Board

3 Phase Auto Transformer

3 Phase Auto Transformer

3 Phase Isolation Transformer

3 Phase Isolation Transformer

Single Phase Dry Type Cast Resin Transformer

Single Phase Dry Type Cast Resin Transformer

ZW8-12 Automatic Circuit Recloser

ZW8-12 Automatic Circuit Recloser

Oil Immersed Distribution Transformer With Conservator

Oil Immersed Distribution Transformer With Conservator

Toroidal Transformer

Toroidal Transformer

Amorphous Alloy Transformer

Amorphous Alloy Transformer

KYN61 40.5 Switchgear

KYN61 40.5 Switchgear

HXGN-12 AC Enclosed Metal Switchgear

HXGN-12 AC Enclosed Metal Switchgear

33kV Substation

33kV Substation

Sf6 Switch

Sf6 Switch

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours